It is an unfaced stone wool board, manufactured in Collector Board which is certified by SPF for outgassing. It is used for the thermal insulation of solar collectors.
| Properties | Symbol | Unit | Description | Tolerance | Standard | |||||
| Material | - | - | Stone Wool | - | TS EN 14303 | |||||
| Material Type | - | - | Collector Board | - | - | |||||
| Width | b | mm | 1100 | +/-1,5% | TS EN 822 | |||||
| Lenght | l | mm | 1700 | +/-2% | TS EN 822 | |||||
| Thickness | d | mm | 30 | 40 | 50 | T4 ** | TS EN 823 | |||
| Coated | - | - | Kaplamasiz | - | - | |||||
| Reaction to Fire Class | - | - | A1 | - | TS EN 13501-1 | |||||
| Thermal Conductivity Declared Value | T | °C | 50 | 100 | 150 | 200 | 250 | 300 | - | TS EN 12667/12939 13787 |
| ?D | W/m.K | 0.041 | 0.051 | 0.065 | 0.082 | 0.101 | 0.124 | |||
| Maximum Service Temperature | - | °C | 600 | - | TS EN 14706 | |||||
| Water Vapor Diffusion Resistance * | µ | - | 1 | - | TS EN 12086 | |||||
| Packaging Material | - | - | PE Film | - | - | |||||
| Other Information | It is SPF (Solartechnik Prüfung Forschung) approved and has successfully passed the "outgassing" test against fogging on the inner surface of the glass. | |||||||||